{"id":4907,"date":"2024-03-26T14:40:21","date_gmt":"2024-03-26T13:40:21","guid":{"rendered":"https:\/\/www.vallourec.com\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/"},"modified":"2024-03-26T14:44:08","modified_gmt":"2024-03-26T13:44:08","slug":"repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2","status":"publish","type":"news","link":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/","title":{"rendered":"Repousser les limites du protocole de test VAM<sup>\u00ae<\/sup> pour l\u2019injection de CO2"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4907\" class=\"elementor elementor-4907 elementor-4900\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8ace9c0 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"8ace9c0\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f1c12c2\" data-id=\"f1c12c2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-450dda0 elementor-widget elementor-widget-spacer\" data-id=\"450dda0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ba8ebb elementor-widget elementor-widget-text_image\" data-id=\"2ba8ebb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text_image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"apply-vallourec-typo\">\n      <div class=\"block sm:flex\">\n      <picture class=\"block sm:hidden w-full mb-4\">\n        <source srcset=\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\" media=\"(max-width: 768px)\">\n        <img decoding=\"async\" src=\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\" alt=\"\" loading=\"lazy\" class=\"w-full h-auto min-w-full min-h-full object-cover select-none pointer-events-none\">\n      <\/picture>\n      <div class=\"sm:w-1\/2 w-full sm:pr-2 pr-0 flex-col flex justify-top\">\n                  <picture class=\"hidden sm:block w-full mb-4\">\n            <source srcset=\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\" media=\"(max-width: 768px)\">\n            <img decoding=\"async\" src=\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\" alt=\"\" loading=\"lazy\" class=\"w-full h-auto min-w-full min-h-full object-cover select-none pointer-events-none\">\n          <\/picture>\n                \n      <\/div>\n      <div class=\"sm:w-1\/2 w-full sm:pl-2 pl-0 flex-col flex justify-top\">\n                <p><div class=\"row \">\r\n        <div class=\"w-full md: col-offset\">\r\n                        \r\n                <p><strong>Les industriels s'int&eacute;ressent plus que jamais au captage et au stockage du carbone (CCS) pour r&eacute;duire les &eacute;missions de CO<sub>2<\/sub>, maintenir le r&eacute;chauffement climatique en dessous de 2&deg;C et acc&eacute;l&eacute;rer la transition &eacute;nerg&eacute;tique. Vallourec a rejoint cette dynamique en 2021 en d&eacute;veloppant un protocole de test validant ses connexions VAM<sup>&reg;<\/sup> pour l'injection de CO<sub>2<\/sub>. Aujourd'hui, avec des commandes de plus en plus nombreuses, Vallourec a d&eacute;cid&eacute; de repousser les limites de son protocole de test, qui garantit l'int&eacute;grit&eacute; de ses produits destin&eacute;s aux applications d'injection de CO<sub>2<\/sub> les plus critiques.<\/strong>\n<br>\n<br>\nLorsque les recherches sur l'injection de dioxyde de carbone ont d&eacute;but&eacute;, certains op&eacute;rateurs ont suppos&eacute; que les conditions de puits seraient similaires &agrave; celles rencontr&eacute;es dans les applications OCTG (Oil Country Tubular Goods). Apr&egrave;s des recherches et des tests plus pouss&eacute;s, nous savons maintenant que les cycles de vie des puits CCS sont beaucoup plus critiques que ceux des puits OCTG, n&eacute;cessitant ainsi des tests sp&eacute;cifiques et plus rigoureux pour valider les produits OCTG destin&eacute;s &agrave; l&rsquo;injection et au stockage de CO<sub>2<\/sub>.<\/p>\r\n        <\/div>\r\n    <\/div><\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cda4644 elementor-widget elementor-widget-spacer\" data-id=\"cda4644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21de205 elementor-widget elementor-widget-title\" data-id=\"21de205\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div>\n      <h2 class=\"title-h2 text-left \" id=\"\">Augmenter la pression et le taux d&#039;injection<\/h2>\n  <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-660f6fa elementor-widget elementor-widget-spacer\" data-id=\"660f6fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-277dc30 elementor-widget elementor-widget-text-editor\" data-id=\"277dc30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Lorsqu&rsquo;un op&eacute;rateur a contact&eacute; Vallourec avec des valeurs de charge sp&eacute;cifiques pour des puits d&rsquo;injection de CO<sub>2<\/sub> et lui a demand&eacute; de valider les connexions VAM<sup>&reg;<\/sup> pour un plus grand nombre de cycles, Vallourec a relev&eacute; le d&eacute;fi. Mais pour pouvoir valider ses connexions &agrave; des performances aussi critiques, Vallourec a d&ucirc; &eacute;tendre son protocole de test d&eacute;velopp&eacute; en 2021.\n<br>\n<br>\n&laquo;<em>\u202fLa phase 1 consiste en une &eacute;valuation op&eacute;rationnelle traditionnelle que l&rsquo;on retrouve dans les protocoles de tests pour les activit&eacute;s p&eacute;trole et gaz<\/em>\u202f&raquo;, explique Pierre Mauger, ing&eacute;nieur R&amp;D chez Vallourec. &laquo;\u202f<em>La phase 2a est celle o&ugrave; les choses commencent &agrave; devenir plus critiques. Nous testons la connexion en 500 cycles &agrave; des temp&eacute;ratures entre 40&deg;C et -20&deg;C et &agrave; une tension constante de 100% CEE1. Et &agrave; 473 bar de pression externe coupl&eacute;e &agrave; la traction, nous sollicitons la connexion jusqu&rsquo;&agrave; sa limite de plastification.<\/em>\u202f&raquo;\n<br>\n<br>\nVient ensuite la phase 2b o&ugrave; la temp&eacute;rature est maintenue stable &agrave; -30&deg;C &agrave; 50% de traction CEE et la pression interne est cycl&eacute;e 500 fois entre 255 +\/- 25 bar. Ces deux phases de cyclage simulent des phases r&eacute;elles d&rsquo;injection de CO<sub>2<\/sub>, en plusieurs injections et sur plusieurs ann&eacute;es d&rsquo;utilisation du puits. La phase 3 permet ensuite d&rsquo;&eacute;valuer la r&eacute;sistance de la connexion dans le cadre d&rsquo;un sc&eacute;nario d&rsquo;&eacute;ruption en abaissant la temp&eacute;rature &agrave; -80&deg;C en moins de 5 minutes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3eeb939 elementor-widget elementor-widget-spacer\" data-id=\"3eeb939\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-846446f elementor-widget elementor-widget-text_image\" data-id=\"846446f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text_image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"apply-vallourec-typo\">\n      <div class=\"block sm:flex\">\n      <picture class=\"block sm:hidden w-full mb-4\">\n        <source srcset=\"https:\/\/www.vallourec.com\/app\/uploads\/2023\/09\/css2.png\" media=\"(max-width: 768px)\">\n        <img decoding=\"async\" src=\"https:\/\/www.vallourec.com\/app\/uploads\/2023\/09\/css2.png\" alt=\"\" loading=\"lazy\" class=\"w-full h-auto min-w-full min-h-full object-cover select-none pointer-events-none\">\n      <\/picture>\n      <div class=\"sm:w-1\/2 w-full sm:pr-2 pr-0 flex-col flex justify-top\">\n                <p><div class=\"row \">\r\n        <div class=\"w-full md: col-offset\">\r\n                        \r\n                <p>Quant &agrave; la phase 4, encore plus critique, elle consiste &agrave; maintenir un delta de temp&eacute;rature de 80&deg;C entre les parties m&acirc;le (pin) et femelle (box) &agrave; 100% de pression pour &eacute;valuer l'&eacute;tanch&eacute;it&eacute; de la connexion apr&egrave;s une d&eacute;pressurisation rapide induisant l'effet Joule-Thomson. &laquo;<em>\u202fC'est un test tr&egrave;s complexe &agrave; r&eacute;aliser\u202f<\/em>&raquo;, explique Pierre Martin, responsable R&amp;D de Vallourec. &laquo;\u202f<em>Pour maintenir le pin &agrave; une temp&eacute;rature tr&egrave;s froide alors qu'il est viss&eacute; &agrave; une box maintenue intentionnellement &agrave; une temp&eacute;rature tr&egrave;s &eacute;lev&eacute;e, nous avons d&ucirc; concevoir de nouvelles mesures et de nouveaux outils de test capables de g&eacute;rer cette diff&eacute;rence de temp&eacute;rature.<\/em>\u202f&raquo;\n<br>\n<br>\nEnfin, la derni&egrave;re phase de test, qui est identique &agrave; la premi&egrave;re, permet de confirmer de mani&egrave;re op&eacute;rationnelle l'&eacute;tanch&eacute;it&eacute; de la connexion apr&egrave;s le retour &agrave; l'&eacute;tat normal du puits.<\/p>\r\n        <\/div>\r\n    <\/div><\/p>\n      <\/div>\n      <div class=\"sm:w-1\/2 w-full sm:pl-2 pl-0 flex-col flex justify-top\">\n                  <picture class=\"hidden sm:block w-full mb-4\">\n            <source srcset=\"https:\/\/www.vallourec.com\/app\/uploads\/2023\/09\/css2.png\" media=\"(max-width: 768px)\">\n            <img decoding=\"async\" src=\"https:\/\/www.vallourec.com\/app\/uploads\/2023\/09\/css2.png\" alt=\"\" loading=\"lazy\" class=\"w-full h-auto min-w-full min-h-full object-cover select-none pointer-events-none\">\n          <\/picture>\n                \n      <\/div>\n    <\/div>\n  <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0231e43 elementor-widget elementor-widget-spacer\" data-id=\"0231e43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4f96ab5 elementor-widget elementor-widget-text-editor\" data-id=\"4f96ab5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Ce nouveau protocole de test comprend 20 % de traction et de compression de plus par rapport \u00e0 notre protocole de 2021, et atteint donc 80 % de limite d&rsquo;\u00e9lasticit\u00e9 de la connexion et 90 % de pression d&rsquo;\u00e9lasticit\u00e9 maximale interne et externe, tout en \u00e9valuant plusieurs cycles d&rsquo;injection suppl\u00e9mentaires (de 75 \u00e0 500). La premi\u00e8re connexion \u00e0 \u00eatre valid\u00e9e selon un protocole d\u2019injection de CO<sub>2<\/sub> aussi rigoureux est le 3 \u00bd\u00a0\u00bb VAM<sup>\u00ae <\/sup>21 CLEANWELL<sup>\u00ae<\/sup>, sachant que d&rsquo;autres connexions et dimensions suivront un peu plus tard dans l&rsquo;ann\u00e9e.\n<br>\n<br>\n\u00ab\u202f<em>Une fois que nous aurons test\u00e9 physiquement plusieurs dimensions de connexions, nous serons en mesure de finaliser notre protocole FEA (Finite Element Assessment) qui permettra d\u2019\u00e9valuer rapidement par simulation des tailles suppl\u00e9mentaires, gr\u00e2ce \u00e0 la comparaison de leurs indicateurs-cl\u00e9s de performance avec ceux des tailles valid\u00e9es physiquement\u202f<\/em>\u00bb, explique Pierre Martin. \u00ab\u202f<em>Cela signifie que lorsqu\u2019un client nous demandera d&rsquo;\u00e9valuer un diam\u00e8tre ext\u00e9rieur sp\u00e9cifique pour une utilisation CCS, le processus sera beaucoup plus rapide que les 6 \u00e0 7 semaines de tests physiques actuels.\u202f<\/em>\u00bb<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56b8f5e elementor-widget elementor-widget-spacer\" data-id=\"56b8f5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3781f9f elementor-widget elementor-widget-title\" data-id=\"3781f9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div>\n      <h2 class=\"title-h2 text-left \" id=\"\">Pr&#234;t pour tous les sc&#233;narios<\/h2>\n  <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b08934c elementor-widget elementor-widget-spacer\" data-id=\"b08934c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f330e4d elementor-widget elementor-widget-text-editor\" data-id=\"f330e4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Avec des commandes de plus en plus nombreuses, la nouvelle version du protocole CCS de Vallourec fournit aux clients des r&eacute;sultats concrets et l&rsquo;assurance dont ils ont besoin pour exploiter en toute confiance leurs puits d&rsquo;injection de CO<sub>2<\/sub>. De plus, la validation de la solution sans graisse CLEANWELL<sup>&reg;<\/sup> offre aux clients une alternative aux rev&ecirc;tements standards, am&eacute;liorant ainsi les performances d&rsquo;installation et r&eacute;duisant le risque environnemental dans le cadre d&rsquo;une offre bas carbone compl&egrave;te. Des tests sur des diam&egrave;tres ext&eacute;rieurs et des grades suppl&eacute;mentaires auront lieu prochainement, offrant ainsi aux op&eacute;rateurs un portefeuille de solutions valid&eacute;es pour une large gamme d&rsquo;applications d&rsquo;injection de CO<sub>2<\/sub>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74ca29f elementor-widget elementor-widget-spacer\" data-id=\"74ca29f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d34dd15 elementor-widget elementor-widget-testimonial\" data-id=\"d34dd15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"testimonial.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"testimonial w-full md:mt-[79px] md:mb-[44px] my-0 relative\">\n  <div class=\"md:block hidden absolute right-0 -top-[79px] custom-padding-right\"><svg width=\"146\" height=\"146\" viewBox=\"0 0 146 146\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n    <path d=\"M125.143 72.2502H84.1787V11.1787H145.25V73.0002C145.25 106.84 117.924 134.414 84.1787 134.817V115.458C107.249 115.056 125.893 96.1647 125.893 73.0002V72.2502H125.143Z\"\n        stroke=\"#009EE0\" stroke-width=\"1.5\" \/>\n    <path d=\"M41.7142 72.2502H0.75V11.1787H61.8215V73.0002C61.8215 106.84 34.4956 134.414 0.75 134.817V115.458C23.8204 115.056 42.4642 96.1647 42.4642 73.0002V72.2502H41.7142Z\"\n        stroke=\"#009EE0\" stroke-width=\"1.5\" \/>\n<\/svg>\n<\/div>\n            <picture class=\"block h-[314px] md:h-[442px] mx-auto md:mx-none w-full max-w-[280px] md:w-[295px] md:-top-[77px] rounded-lg relative md:absolute shadow shadow-1 overflow-hidden\">\n        <source srcset=\"\" media=\"(max-width: 768px)\">\n        <img decoding=\"async\" src=\"https:\/\/www.vallourec.com\/app\/uploads\/2024\/03\/diana-rodriguez.jpg\" alt=\"\" loading=\"lazy\" class=\"w-full h-auto min-w-full min-h-full object-cover select-none pointer-events-none\">\n      <\/picture>\n        <div class=\"relative -z-10 flex flex-col min-h-[321px] md:pt-[55px] md:custom-padding-right p-4 md:pl-[109px] md:ml-[234px] md:mt-0 mt-12 rounded-lg md:rounded-none bg-blue-secondary-200\">\n    <div class=\"block md:hidden absolute right-0 -top-[30px]\"><svg width=\"50\" height=\"50\" viewBox=\"0 0 50 50\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path d=\"M42.857 24.2501H29.3213V4.32153H49.2499V25.0001C49.2499 36.1513 40.3775 45.2692 29.3213 45.6653V40.0174C37.2654 39.6253 43.607 33.0399 43.607 25.0001V24.2501H42.857Z\" stroke=\"#009EE0\" stroke-width=\"1.5\"\/>\n<path d=\"M14.2857 24.2499H0.75V4.32129H20.6786V24.9999C20.6786 36.1511 11.8062 45.269 0.75 45.6651V40.0171C8.69411 39.6251 15.0357 33.0396 15.0357 24.9999V24.2499H14.2857Z\" stroke=\"#009EE0\" stroke-width=\"1.5\"\/>\n<\/svg>\n<\/div>\n    <div class=\"pb-[24px] text-blue-secondary-800 italic leading-[40px] flex flex-col justify-center flex-1\"><p>Nous constatons actuellement une forte acc\u00e9l\u00e9ration du march\u00e9, qui se concr\u00e9tise avec plusieurs dizaines de projets CCS \u00e0 un stade avanc\u00e9 d'ing\u00e9nierie. Nous avions anticip\u00e9 cette dynamique, en collaborant avec nos clients et en int\u00e9grant dans nos protocoles de tests physiques, un certain nombre de conditions extr\u00eames. Aujourd'hui, nous sommes pr\u00eats \u00e0 fournir \u00e0 tous les op\u00e9rateurs CCS des connexions test\u00e9es selon les protocoles destin\u00e9s aux projets CCS les plus exigeants\u202factuellement disponibles dans l'industrie.<\/p><\/div>\n    <div class=\"pb-[28px] flex flex-col\">\n      <div class=\"title-h6\">Diana Rodriguez<\/div>\n      <div class=\"text-subtitle text-grey-700\">Responsable du d&#233;veloppement CCS chez Vallourec<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Les industriels s&rsquo;int\u00e9ressent plus que jamais au captage et au stockage du carbone (CCS) pour r\u00e9duire les \u00e9missions de CO2<\/p>\n","protected":false},"author":0,"featured_media":4902,"template":"","meta":{"_acf_changed":false},"categories":[229],"tags":[],"class_list":["post-4907","news","type-news","status-publish","has-post-thumbnail","hentry","category-vam"],"acf":[],"yoast_head":"<title>Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2 - Vallourec<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2 - Vallourec\" \/>\n<meta property=\"og:description\" content=\"Les industriels s&#039;int\u00e9ressent plus que jamais au captage et au stockage du carbone (CCS) pour r\u00e9duire les \u00e9missions de CO2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/\" \/>\n<meta property=\"og:site_name\" content=\"Vallourec\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/fr-fr.facebook.com\/Vallourec\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-26T13:44:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2063\" \/>\n\t<meta property=\"og:image:height\" content=\"1547\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@Vallourec\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/\",\"url\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/\",\"name\":\"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2 - Vallourec\",\"isPartOf\":{\"@id\":\"https:\/\/www.vallourec.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\",\"datePublished\":\"2024-03-26T13:40:21+00:00\",\"dateModified\":\"2024-03-26T13:44:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#primaryimage\",\"url\":\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\",\"contentUrl\":\"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg\",\"width\":2063,\"height\":1547},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"News\",\"item\":\"https:\/\/www.vallourec.com\/fr\/news\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.vallourec.com\/fr\/#website\",\"url\":\"https:\/\/www.vallourec.com\/fr\/\",\"name\":\"Vallourec\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.vallourec.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.vallourec.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.vallourec.com\/fr\/#organization\",\"name\":\"Vallourec\",\"url\":\"https:\/\/www.vallourec.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.vallourec.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.vallourec.com\/app\/uploads\/2024\/11\/vallourec_logo.jpg\",\"contentUrl\":\"https:\/\/www.vallourec.com\/app\/uploads\/2024\/11\/vallourec_logo.jpg\",\"width\":662,\"height\":500,\"caption\":\"Vallourec\"},\"image\":{\"@id\":\"https:\/\/www.vallourec.com\/fr\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/fr-fr.facebook.com\/Vallourec\/\",\"https:\/\/x.com\/Vallourec\",\"https:\/\/www.instagram.com\/vallourec\/\",\"https:\/\/fr.linkedin.com\/company\/vallourec\",\"https:\/\/www.youtube.com\/channel\/UCgIl0xm1ANwajVkfCFvZr0w\"]}]}<\/script>","yoast_head_json":{"title":"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2 - Vallourec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/","og_locale":"fr_FR","og_type":"article","og_title":"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2 - Vallourec","og_description":"Les industriels s'int\u00e9ressent plus que jamais au captage et au stockage du carbone (CCS) pour r\u00e9duire les \u00e9missions de CO2","og_url":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/","og_site_name":"Vallourec","article_publisher":"https:\/\/fr-fr.facebook.com\/Vallourec\/","article_modified_time":"2024-03-26T13:44:08+00:00","og_image":[{"width":2063,"height":1547,"url":"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@Vallourec","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/","url":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/","name":"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2 - Vallourec","isPartOf":{"@id":"https:\/\/www.vallourec.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#primaryimage"},"image":{"@id":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#primaryimage"},"thumbnailUrl":"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg","datePublished":"2024-03-26T13:40:21+00:00","dateModified":"2024-03-26T13:44:08+00:00","breadcrumb":{"@id":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#primaryimage","url":"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg","contentUrl":"https:\/\/www.vallourec.com\/app\/uploads\/2022\/12\/CSS1.jpg","width":2063,"height":1547},{"@type":"BreadcrumbList","@id":"https:\/\/www.vallourec.com\/fr\/news\/repousser-les-limites-du-protocole-de-test-vam-pour-linjection-de-co2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"News","item":"https:\/\/www.vallourec.com\/fr\/news\/"},{"@type":"ListItem","position":2,"name":"Repousser les limites du protocole de test VAM\u00ae pour l\u2019injection de CO2"}]},{"@type":"WebSite","@id":"https:\/\/www.vallourec.com\/fr\/#website","url":"https:\/\/www.vallourec.com\/fr\/","name":"Vallourec","description":"","publisher":{"@id":"https:\/\/www.vallourec.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.vallourec.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.vallourec.com\/fr\/#organization","name":"Vallourec","url":"https:\/\/www.vallourec.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.vallourec.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.vallourec.com\/app\/uploads\/2024\/11\/vallourec_logo.jpg","contentUrl":"https:\/\/www.vallourec.com\/app\/uploads\/2024\/11\/vallourec_logo.jpg","width":662,"height":500,"caption":"Vallourec"},"image":{"@id":"https:\/\/www.vallourec.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/fr-fr.facebook.com\/Vallourec\/","https:\/\/x.com\/Vallourec","https:\/\/www.instagram.com\/vallourec\/","https:\/\/fr.linkedin.com\/company\/vallourec","https:\/\/www.youtube.com\/channel\/UCgIl0xm1ANwajVkfCFvZr0w"]}]}},"_links":{"self":[{"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/news\/4907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/types\/news"}],"version-history":[{"count":3,"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/news\/4907\/revisions"}],"predecessor-version":[{"id":16229,"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/news\/4907\/revisions\/16229"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/media\/4902"}],"wp:attachment":[{"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/media?parent=4907"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/categories?post=4907"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vallourec.com\/fr\/wp-json\/wp\/v2\/tags?post=4907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}